Submersible Pump Problems and Troubleshooting

No water, falling flow, an overload relay that keeps tripping, a burnt motor winding. The most common submersible pump problems and motor faults, how to recognise them and how to fix them.

Safety first

Before you start troubleshooting

Every check on the control panel and motor must be carried out with the power isolated and by a qualified electrician. This guide lists possible causes; for measured values, always refer to the motor nameplate and datasheet. If the same failure keeps recurring, find the cause before replacing parts: otherwise the new pump or motor will fail the same way.

The pump runs but delivers no water
Possible causeHow to recognise itRemedy
Water level has dropped below the pump intakeWater flows briefly and then stops, current is lowCheck the setting depth against the dynamic water level; fit dry-run protection and match the flow to the well yield
Motor is running in reverseLittle water, pressure lower than expectedSwap two of the three phases and compare the pressure; the direction giving higher pressure is correct
Non-return valve fitted backwards or stuckPump runs, no flow at the outletCheck the valve direction and that it opens and closes freely
Broken rising main or major leakPressure does not build, weak flow at the well headPull the pump and inspect the pipe joints
Coupling or shaft failure between motor and pumpMotor draws normal current but no water at allPull the pump and check the shaft coupling; the shaft should turn freely by hand
Flow and pressure have dropped over time
Possible causeHow to recognise itRemedy
Sand wear on impellers and diffusersSandy well, slow and steady loss of performanceReplace worn parts; reduce sand using the steps in the sand guide
Deposits on the intake strainer or hydraulic surfacesWater high in iron or manganesePull and clean the pump; plan periodic cleaning
Dynamic water level has fallenSeasonal decline or neighbouring wellsMeasure the level; lower the pump or reduce the flow if necessary
Leak in the pipelinePump performance normal but less water reaches the delivery pointInspect the surface pipeline and connections
Low voltage or wrong frequencyLow motor speed, high currentMeasure the voltage at the motor supply while running
Motor running in reverse (after new installation or maintenance)Performance low from the startCheck the direction of rotation
The overload relay keeps tripping
Possible causeHow to recognise itRemedy
Low or unbalanced supply voltageCurrent differs between phases, voltage below nameplateMeasure voltage and phase balance; use an under/overvoltage relay
Phase lossMotor hums, current zero on one phaseCheck fuses, contactor and cable splices; fit a phase failure relay
Pump strained or jammed by sandVery high current at startPull and clean the pump; if the shaft does not turn by hand, do not keep attempting to start
Overload relay set incorrectlyCurrent below nameplate but the relay tripsSet the relay to the motor rated current
Cable cross-section too smallVoltage drops noticeably at startRecalculate the cable for the installed depth; see the cable sizing guide
Pump running at very low head and very high flowValve fully open, high currentCheck the duty point; throttle the flow with a valve or review the pump selection
The motor does not start at all
Possible causeHow to recognise itRemedy
No power or blown fuseNo voltage at the panelCheck the supply, fuses and contactor
Protection relay has trippedDry-run or phase relay showing a faultFind why the relay tripped; check water level and phase condition
Cable or splice failureNo continuity on one or more phasesMeasure cable continuity and check the splices
Winding or insulation failureInsulation resistance below the minimum stated by the motor manufacturerPull the motor; identify the cause of the burnout before rewinding
Pump jammed by sandHigh current at start, motor does not turnPull and clean the pump
The pump starts and stops too often
Possible causeHow to recognise itRemedy
Pressure switch or pressure tank set incorrectlySwitches on and off at short intervalsCheck the switch settings and tank pre-charge pressure
Well yield lower than pump flowDry-run protection trips frequentlyReduce the flow, extend running time or add storage
Non-return valve leakingPressure falls quickly after the pump stopsInspect or replace the non-return valve
The motor winding keeps burning out
Possible causeHow to recognise itRemedy
Insufficient coolingWide casing or pump set below the screenCalculate the annular velocity; fit a flow sleeve if needed
Voltage dropLong cable, voltage dips at startSize the cable for the installed depth
Phase loss or imbalanceUnstable supplyUse a phase failure relay
Too many startsMany starts and stops per hourReview the control system and tank volume
Dry runningWater level occasionally falls below the intakeFit dry-run protection

Most recurring winding failures are caused by installation decisions, not manufacturing faults. See the motor cooling guide for details.

Noise, vibration or sand in the water
Possible causeHow to recognise itRemedy
Water level low, pump drawing airIntermittent flow, aerated waterLower the pump or reduce the flow
Bearing wearIncreasing noise and vibration, sandy wellPull the pump and inspect the bearings
Well not properly developedSand in the water continuouslyHave the well developed by your driller; reduce flow, use a sand separator
Flow too high for the well yieldExcessive drawdown, more sand at each startMatch the flow to the well yield; use soft starting
Six rules that prevent most failures
01

Size on the dynamic water level

A pump sized on the static level ends up undersized and close to dry running.

02

Fit complete protection

Overload, dry-run and phase failure protection prevent the majority of failures.

03

Size the cable for the depth

The cable must be sized for the total length, not only for the motor rating.

04

Check motor cooling

Use a flow sleeve in wide casings and when the pump is set below the screen.

05

Commission correctly

Check the direction of rotation and record the first readings; see the installation guide.

06

Record readings regularly

Logging current, voltage, flow and pressure periodically reveals problems before they become failures.

Frequently asked questions

Will a submersible pump deliver water if it runs in reverse?

Usually it delivers some water, but pressure and flow are noticeably lower, which is why reverse rotation often goes unnoticed. Check the direction of rotation after every new installation and every electrical service.

What happens if a submersible pump runs dry?

The water-filled motor and the pump bearings rely on water for cooling and lubrication. Dry running can quickly damage the bearings and the motor. Dry-run protection eliminates this risk.

What should I do when the motor winding burns out?

First identify the cause: voltage, phase loss, cooling, sand or dry running. FANPO motors are rewindable, but a motor rewound without removing the cause will fail the same way.

Why does the overload relay keep tripping?

The most common causes are low or unbalanced voltage, phase loss, sand strain, an undersized cable and an incorrect relay setting. Measuring current and voltage on all three phases while running usually reveals the cause.

What information should I send FANPO for troubleshooting?

Send the pump and motor model, setting depth, dynamic water level, cable length and cross-section, running current and voltage, and a short description of the symptom through the contact page.